![]() Protocol: TCP/IP Ethernet 100 Mbit Standard: POCT1-A2 ![]() Glucose Results in 6 Seconds, Ketone Results in 10 Seconds.(ADA recommends ketone testing when glucose >250 mg/dL or >14 mmol/L) StatStrip Glucose/Ketone Connectivity Meter To learn more about how StatStrip Glucose can bring critical care testing to the bedside, contact your current GPO or call Nova at 80. In order to help hospitals avoid the risk of glucose meter off-label use, Nova Biomedical’s technical support resources are ready to help you acquire the StatStrip Glucose Hospital Meter System. *Ketone testing is not available with StatStrip meters in the U.S. ![]() Urine testing can also produce false positive or negative results due to highly colored urine, highly acidic urine, exposure of the urine test strips to air for prolonged periods, drugs such as the ACE inhibitor captopril, or high doses 2īlood ketone is more accurate than urine ketone testingīlood beta-hydroxyburyrate testing indicates the patient’s status at the time of the test, whereas urine may have been in the bladder for several hours. The mean lag between the blood ketone and urine ketone groups was 11 hours, ranging from 1 to 36 hours. The pH/īlood ketone endpoint was reached after 17 hours, whereas the pH/urine ketone endpoint was not reached until 28 hours after starting treatment. 1Ī second study of DKA patients compared a DKA therapy endpoint of pH > 7.3 and blood ketones 7.3 and negative urine ketones. This led to savings of 22 hours of nursing time and 375 laboratory investigations, for a total savings of €2,940. The blood ketone testing group of patients left the ICU 6.5 hours earlier than the urine ketone testing group. They are also easier to obtain and allow for immediate reflex testing of ketones whenever glucose is greater than 14 mmol/L.īlood ketone monitoring reduces costs and ICU length of stay for DKA patientsĪn ICU study evaluated the effectiveness of blood ketone testing versus urine ketone testing for DKA patients. Ketone testing results obtained from capillary samplesĬapillary blood samples are not only preferred over urine samples to detect and monitor DKA, StatStrip Glucose/Ketone measures blood beta-hydroxybutyrate, the preferred ketone for diagnosing ketoacidosisĪccording to the European Society for Paediatric Endocrinology, Diabetes UK, ADA, and others, blood ketone testing methods that quantify beta-hydroxybutyrate, the predominant ketone body in DKA, are recommended over urine ketone testing for diagnosing and monitoring ketoacidosis. Insert a ketone strip and StatStrip Glucose/Ketone meter automatically recognizes the strip and converts the meter to ketone measuring mode.īlood ketone testing should be performed whenever glucose exceeds 14 mmol/L (250 mg/dL)ĭiabetes UK, the Canadian Diabetes Association, the European Society for Paediatric Endocrinology, and the American Diabetes Association (ADA) recommend that blood ketone testing be performed whenever glucose exceeds 14 to 17 mmol/L for rapid detection or prevention of diabetic ketoacidosis (DKA). No meter preparation or calibration coding steps are required.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |